Cortex
Synapse PDM Configuration Utility
About Cortex
Cortex is a desktop application for configuring, monitoring and updating Synapse PDM controllers. Built with C#/.NET and Avalonia UI, it provides:
- System, CAN bus, input, output and I/O Flow configuration
- Live status monitoring and data charts
- Log download, analysis and map views
- Firmware updates and local configuration files
- Telemetry configuration
- Windows, Linux and macOS support
Installation
Download Cortex from the GitHub releases page.
Windows: Download and run the release's setup.exe installer.
Linux: Download and extract the .tar.gz archive. From a terminal in the extracted folder, run:
chmod +x Cortex./Cortex
You may need to add your user to the dialout group to access the serial port: sudo usermod -aG dialout username.
macOS: Download the osx-x64.tar.gz or osx-arm64.tar.gz archive for your Mac, extract it, then run the Cortex executable from the extracted folder.
Connection

Connecting to a controller
Choose a serial port and select CONNECT. REFRESH rescans the available ports, and DISCONNECT ends the current connection.
Configuration files
Use File > Open to load a local configuration and File > Save to save a configuration file as a backup. These menu actions work with local files; use SAVE CHANGES to apply pending settings to the connected controller.
System status log
The status log shows Cortex events while the PDM is connected, with the newest events at the top.
Status indicators
When connected, the main-window footer shows connection, SD log, GPS, system current, system voltage and system temperature status. Green indicates healthy; red indicates a fault.
Status

System metrics
Live system temperature, system current, battery voltage and mobile signal strength are shown above the channel table.
Channel status and override
The channel table displays live output status and analogue values in their configured units. To override an output, click and hold Inactive in that channel's Input Override cell. The output continues to obey configured current limits. Click the cell again to cancel the override.
An override is also cleared when Cortex disconnects, or when the PDM enters standby or power cycles.

Warning: Use the override feature with caution.
Live chart
Use the Live Data Channel and Live Data Analogue Inputs legends to choose which output channels and analogue inputs appear in the chart. The chart shows up to one minute of live data.
Pause and resume
Pause stops chart updates. Resume returns the chart to the current time.
Secondary Y axis
Analogue inputs with different units are displayed against an additional Y axis.
Log History

Logs on the controller
Refresh the list to see logs stored on the PDM. The controller keeps up to 10 logs. Reset deletes the stored logs and starts a new one.
Select a log and choose Download to copy it to the computer. On Windows, downloaded logs are stored in Documents\Synapse PDM Logs. A tick beside a log indicates that Cortex has found its downloaded file on disk.
Use Browse to open a log from another location. It must be in a format Cortex can read. The status area shows download progress; download time varies with the amount of data recorded.
Log charts and metrics
After loading a log, use Parameters to select data for the chart. The Metrics view displays the log metrics table.
Set the start and end date/time to choose the chart and map range. Enable crosshairs to read chart values. Zoom with the mouse wheel and pan by clicking and dragging.


Map
The map displays recorded GPS coordinates at 1 Hz. Other logged data is recorded at 10 Hz; for each GPS point, the corresponding ten data points appear in the parameter grid.

I/O Flow
I/O Flow replaces the former I/O Settings editor. It configures input sources, output channels, logic rules and CAN message links as a node graph.

Working with the canvas
- Right-click the canvas to add nodes, remove or restore nodes, and arrange the graph. Drag a wire from an output connector to an input connector to create a connection.
- Select one node to edit its settings in the Node properties panel. The panel can be resized and scrolls independently of the canvas.
- Use Auto arrange to lay out nodes by connected source. Undo or Ctrl+Z reverses the last 10 node moves, auto-arranges or connection changes.
- Add up to 20 named canvases with the + button. Right-click a canvas tab to rename it or delete it; only empty canvases can be deleted.
- The Canvas preview minimap shows the current canvas. Click or drag in the minimap to pan the main view.
- Node positions and canvas layout are saved locally. Controller configuration changes remain pending until SAVE CHANGES; REVERT CHANGES discards pending controller changes.
- Digital Input, Analogue Input, Output Channel, CAN RX Signal and System Value nodes show rolling 10-second mini charts. Other node types do not show a chart.
A digital input, analogue input or ignition source can drive more than one output channel. Each output channel has one incoming control connection. CAN RX signal and system-value nodes are sources for logic-rule operands; use the System CAN Input node for CAN-controlled output channels.
Warning: Connecting a source to an Output Channel stages that channel's enable flag. SAVE CHANGES applies the change to the controller, so verify the output and its connected load are safe before saving.
Node types
Digital Input
Selects one of the PDM's dedicated digital inputs. The electrical mode is fixed as active high; polarity is not configurable. The properties panel shows the live electrical state as High, Low or Unknown.

Analogue Input
Selects one of the analogue-capable inputs and edits that input's existing configuration. The node shows live connector voltage and converted value. Any logic rules and output connections follow the node if its source is changed.
Settings depend on the input type:
- Input type: Raw Voltage, Active, Passive, NTC or Digital.
- Units: Select engineering units where available. Supported choices include volts, amps, Celsius, Fahrenheit, percent, RPM, KPH, MPH, bar and PSI. Raw Voltage and Digital use volts; NTC uses Celsius or Fahrenheit.
- Calibration points: Active and Passive modes support two or three voltage/value calibration points.
- Range minimum / maximum: Sets the configured range for calibrated inputs.
- NTC Beta and NTC resistance at 25°C: Shown for NTC mode.
- Pull-up resistor and Pull-down resistor: Shown only for modes that support the internal resistors. The input configuration does not allow both to be enabled at once.
For an analogue input configured as Digital, a pull-up makes the connector active-low and a pull-down makes it active-high. This is separate from the dedicated digital inputs, which are always active-high.

Ignition On
A fixed ignition-input source. It has no editable settings; connect it to output channels that should follow ignition state.

System CAN Input
A fixed CAN input source for CAN-controlled outputs. Connect it directly to output-channel nodes that use CAN Digital or CAN PWM behavior. This is distinct from decoded Custom CAN RX signals, which are used as logic-rule inputs.

CAN RX Signal
A source node for one enabled, decoded signal on a Custom CAN receive message. Select the signal in Source assignment; its live value is shown on the node. Configure the receive message and signal first in CAN Messages. CAN RX signal nodes connect to logic-rule operands, not directly to output channels.

System Value
A source node for one controller value. Select the source in Source assignment; the live value is shown on the node. Available values are:
- System temperature
- SIM module temperature
- IMU temperature
- Battery voltage
- System current
- Acceleration X, Y and Z
- Gyroscope X, Y and Z
- Magnetic field X, Y and Z
System Value nodes connect to logic-rule operands.

Logic Rule
Combines connected sources and constants. Connect source nodes to the A and, when the selected operation needs it, B input. The properties panel shows live operand values, the rule result and output/rule usage.
Settings:
- Operation:
ADD,SUBTRACT,MULTIPLY,DIVIDE,GREATER_THAN,GREATER_EQUAL,LESS_THAN,LESS_EQUAL,EQUAL,NOT_EQUAL,AND,OR,XOR,NOT,MIN,MAX,ABSorTOGGLE. - Operand A source and Operand B source: Select a source already wired to the corresponding connector, or select a constant and enter its value.
NOT,ABSandTOGGLEuse Operand A only. - Hysteresis: Available for
GREATER_THAN,GREATER_EQUAL,LESS_THANandLESS_EQUAL. When enabled, set separate ON threshold and OFF threshold values to avoid chatter near a comparison boundary.
Rules can use digital inputs, analogue inputs, output channels, other logic rules, CAN RX signal nodes, system values or constants. Logic connections cannot contain cycles.

Output Channel
Represents one physical output channel. The properties panel shows live current and active state. Select an available output channel, assign its Category, and set its three-character Channel name. The control source is assigned by wiring into the node.
Available Output behaviour options depend on the connected source:
- Digital input or Ignition On: Digital, Digital PWM or Intermittent.
- Analogue input: Analogue threshold or Analogue scaled PWM.
- System CAN Input: CAN Digital or CAN PWM.
- A math-controlled output uses Output behaviour set to Digital or PWM. Digital treats zero as OFF and nonzero as ON; PWM uses the connected logic result as a 0–100% duty value.
Other settings are shown as applicable:
- Duty (%): Fixed PWM duty for compatible channel behaviors.
- Retry count: Automatic restart attempts after a channel fault before lockout (0–10).
- Current tab:
- Threshold low: Undercurrent/open-circuit threshold (0–17 A).
- Threshold high: Overcurrent threshold (0–17 A).
- Inrush delay: Time after turn-on during which the inrush limit applies (0–2 seconds).
- Inrush limit: Temporary startup current limit (0–50 A).
- Analogue tab:
- Threshold behavior selects ON above / OFF below or ON below / OFF above, with separate ON and OFF thresholds in the input's units.
- Scaled PWM behavior maps Scale min / Scale max input values to PWM minimum / PWM maximum output duty.
- Timing tab:
- Intermittent ON / Intermittent OFF: Cycle durations from 0 to 10 seconds.
- Delayed ON / Delayed OFF: Enable each delay, choose milliseconds, seconds or minutes, and set its duration.
- Delayed OFF trigger: Start the delay when ignition turns off or when the assigned input turns off.
- Soft start / Soft stop: Enable output ramps and set the ramp duration from 0 to 5 seconds.

CAN TX
Transmits a stored Custom CAN TX message when triggered. Select the stored message, enable or disable it, and choose One-shot or Periodic mode. One-shot sends when its trigger turns on; Periodic repeats while the trigger is active.
For Periodic mode, set Period (ms) from 100 to 30,000 ms in 100 ms steps. Connect an Output Channel node to assign the trigger channel. The CAN TX node has no output connector. Configure the frame and signals in CAN Messages.

Custom CAN Messages
The CAN Messages tab lets you import signals from a DBC file or define CAN frames and signals manually. CAN RX Signal and CAN TX nodes in I/O Flow use these stored definitions.

DBC Import
- Select Import DBC File and open the DBC file.
- Filter the signal list by signal name if needed.
- Review the message, message ID, ID type, signal, start bit, bit length, minimum, maximum and units.
- Select the signals to add and choose Import Selected Signals.
The importer skips multiplexed signals because conditional decoding is not supported. It also skips independent signals that are not associated with a CAN message. Cortex reports the number of skipped signals in the import status and system log.
Manual Entry
Define a message (CAN frame), then add its signals. To add a signal to an existing stored frame, select that message; its frame settings are then fixed.
Message settings
- Name: Optional display name, up to 64 characters. It is stored locally by Cortex. If blank, Cortex uses
MSG_<ID>. - ID (Hex): Standard identifiers range from
0x000to0x7FF. Extended identifiers can be up to0x1FFFFFFF. - Extended (29-bit): Select for extended frames. It is required for IDs above
0x7FF; it can also be used for a low numeric ID sent as an extended frame. - DLC: Frame data length, 1–8 bytes. Every signal must fit within
DLC × 8bits. - Direction:
- RX decodes signals from frames received on the bus.
- TX one-shot sends once when its trigger turns on.
- TX periodic repeats at its configured interval while the trigger is active.
- Timeout / period: For RX, milliseconds without a frame before its signals are marked timed out;
0disables the timeout. For TX periodic, this is the transmit period (1–60,000 ms). It is unused for TX one-shot. - Trigger (TX only): Always or an output channel. A channel trigger is active only while that output is on; one-shot sends at each off-to-on transition.
Signal settings
- Name: Optional display name, up to 64 characters; stored locally by Cortex.
- Start Bit: DBC bit position, 0–63.
- Bit Length: 1–64 bits. The signal must fit inside the frame's DLC.
- Motorola endian: Select for big-endian Motorola numbering; leave clear for little-endian Intel.
- Signed: Interpret the raw value as two's-complement signed; leave clear for unsigned.
- Factor and Offset: Convert raw to physical units using
physical value = raw × Factor + Offset. Factor must be non-zero except for a TX signal using a Constant source. - Min / Max: Optional expected physical-value limits; Min must not exceed Max.
- Units: Optional engineering units, up to 32 characters.
- Source (TX only): Constant sends the Offset as the raw value. Channel N uses that output channel's live value, scaled by Factor and Offset. Custom CAN TX payload sources are constants or output-channel values.
Choose Add Signal to Controller to write the signal and, when new, its message. Invalid fields are rejected and shown in the validation summary.
Stored Messages and signals
- The Stored Messages table shows each frame's name, ID, ID type, DLC, direction, trigger, timeout, period, signal count and slot.
- RX/TX direction applies to the whole frame and all its signals. Select one or more messages, choose a direction and press Apply.
- Delete Checked Messages queues deletion of each selected message and all its signals. Clear All queues deletion of every stored message and signal.
- In the selected message's signal table, signal names can be edited. Delete Checked Signals removes selected signals; removing the last signal also removes its message.
- Deletions are pending controller changes. Use SAVE CHANGES to apply them.
- The Frame Layout view shows the bits used by each signal. Click a bit to select its signal. Overlapping signals are outlined in red; bytes beyond the DLC are hatched.
A CAN TX message must also have a CAN TX node in I/O Flow to be assigned to an output trigger. Changing a message to RX removes its TX node. A CAN RX Signal node is available only for an enabled signal on an RX message.
Connector View
The Connector tab shows the 35-way Ampseal connector diagram, a color legend and a read-only pin summary. Hover over the diagram to identify a pin; use the table to cross-reference the physical role with its configured type, settings, active state, live reading and protection/scaling details.

35-way Ampseal pin reference
| Pin | Physical role | Pin | Physical role | Pin | Physical role | Pin | Physical role |
|---|---|---|---|---|---|---|---|
| 1 | Output 3 | 2 | Output 4 | 3 | Output 5 | 4 | Output 6 |
| 5 | Output 7 | 6 | CAN L | 7 | CAN H | 8 | Output 8 |
| 9 | Output 9 | 10 | Output 10 | 11 | Output 11 | 12 | Output 12 |
| 13 | Output 2 | 14 | Digital input 1 | 15 | Digital input 2 | 16 | Digital input 3 |
| 17 | Digital input 4 | 18 | Digital input 5 | 19 | Digital input 6 | 20 | Digital input 7 |
| 21 | Digital input 8 | 22 | Ignition | 23 | Output 13 | 24 | Output 1 |
| 25 | Analogue input 1 | 26 | Analogue input 2 | 27 | Analogue input 3 | 28 | Analogue input 4 |
| 29 | Analogue input 5 | 30 | Analogue input 6 | 31 | Analogue input 7 | 32 | Analogue input 8 |
| 33 | 5V Reference | 34 | Ground | 35 | Output 14 |
System Settings Tab

1. GSM / Data / GPS
- Cellular data - Enable or disable mobile data connections.
- GPS - Enable or disable GPS position, speed and time data.
- APN, APN user and APN password - Enter the access point details supplied by the SIM provider. Username and password are optional when the provider does not require them.
- Publish interval - Target interval in seconds for selected telemetry uploads (5–3600 seconds). Upload is best effort; signal quality and other controller tasks can affect delivery.
- Telemetry uploads - Select which system voltage, system current, temperature, uptime, GPS, IMU, channel current, digital input and analogue input values to upload.
- OpenRemote sign-in - Enter the telemetry-service realm, username and password. Stay signed in on this computer saves the session on the host; use Sign out to end it.
- PDM name - The name used for the PDM in the telemetry service. It must be unique within the organisation.
- Provision PDM - Register the connected PDM in the selected realm.
- Rename PDM and Unregister PDM - Manage the PDM's telemetry-service registration.
- Connection status - Shows cellular connection health and provisioning status.
2. System
- Controller date and time - Set the PDM's real-time clock when GPS is disabled or unavailable. Choose the date, time and time zone, then send them to the controller.
- Controller timezone - The selected time zone supplies daylight-saving rules for automatic clock updates. Cortex marks zones with unsupported daylight-saving rules; the controller stores a recurring rule based on the selected clock year and following four years. Changes to the computer's time-zone data or daylight-saving legislation are not applied automatically; set the controller time and time zone again after those changes.
- Motion detection - Enable or disable motion detection while the PDM is in sleep mode.
- Distance units - Metric or imperial.
- Speed units - Metric or imperial.
- System current limit - Sets the total current limit for the PDM, up to 150 A.
3. CAN
- CAN bus resistor - Enable or disable the internal CAN bus termination resistor.
- CAN bus bitrate - Set the CAN bitrate for the PDM.
- CAN bus addresses - Configure the CAN message IDs used by the PDM. See the CAN page for details.
- Custom CAN messages - Define or import message frames and signals in the Custom CAN Messages section.
4. Updates
- Cortex app - Shows the installed and latest Cortex versions and links to the latest releases. To update Cortex, download and install the latest installer over the existing installation.
- System Firmware - Cortex checks for firmware releases and can install a release or local firmware package. The controller verifies firmware before updating through its built-in bootloader.
- Factory Reset - Resets the controller to factory settings. Factory reset does not disable an enabled PIN lock.
- PIN Lock - Configure or change the 4-digit PIN used for secure USB access, or disable PIN lock using an authorized secure session. Configuration imports do not remove the PIN lock; use the authorized disable action.
Revert and Save
Once changes have been made, REVERT CHANGES and SAVE CHANGES become available. Revert discards pending controller changes; Save sends them to the controller.
Wait for the save to complete before disconnecting the controller.
Settings Save Status
The main window footer shows Updating PDM while settings are being saved. Afterward, it displays the time settings were last saved to the controller. This is a settings-save timestamp, not a firmware-update or controller-clock timestamp.