Synapse PDM Configuration Utility

About Cortex

Cortex is a desktop application for configuring, monitoring and updating Synapse PDM controllers. Built with C#/.NET and Avalonia UI, it provides:

Installation

Download Cortex from the GitHub releases page.

Windows: Download and run the release's setup.exe installer.

Linux: Download and extract the .tar.gz archive. From a terminal in the extracted folder, run:

You may need to add your user to the dialout group to access the serial port: sudo usermod -aG dialout username.

macOS: Download the osx-x64.tar.gz or osx-arm64.tar.gz archive for your Mac, extract it, then run the Cortex executable from the extracted folder.

Connection

screenshot_2026-11-14_201343.png

Connecting to a controller

Choose a serial port and select CONNECT. REFRESH rescans the available ports, and DISCONNECT ends the current connection.

Configuration files

Use File > Open to load a local configuration and File > Save to save a configuration file as a backup. These menu actions work with local files; use SAVE CHANGES to apply pending settings to the connected controller.

System status log

The status log shows Cortex events while the PDM is connected, with the newest events at the top.

Status indicators

When connected, the main-window footer shows connection, SD log, GPS, system current, system voltage and system temperature status. Green indicates healthy; red indicates a fault.

Status

screenshot_2026-11-14_201358.png

System metrics

Live system temperature, system current, battery voltage and mobile signal strength are shown above the channel table.

Channel status and override

The channel table displays live output status and analogue values in their configured units. To override an output, click and hold Inactive in that channel's Input Override cell. The output continues to obey configured current limits. Click the cell again to cancel the override.

An override is also cleared when Cortex disconnects, or when the PDM enters standby or power cycles.

screenshot_2026-11-14_203958.png

Warning: Use the override feature with caution.

Live chart

Use the Live Data Channel and Live Data Analogue Inputs legends to choose which output channels and analogue inputs appear in the chart. The chart shows up to one minute of live data.

Pause and resume

Pause stops chart updates. Resume returns the chart to the current time.

Secondary Y axis

Analogue inputs with different units are displayed against an additional Y axis.

Log History

screenshot_2026-11-14_204258.png

Logs on the controller

Refresh the list to see logs stored on the PDM. The controller keeps up to 10 logs. Reset deletes the stored logs and starts a new one.

Select a log and choose Download to copy it to the computer. On Windows, downloaded logs are stored in Documents\Synapse PDM Logs. A tick beside a log indicates that Cortex has found its downloaded file on disk.

Use Browse to open a log from another location. It must be in a format Cortex can read. The status area shows download progress; download time varies with the amount of data recorded.

Log charts and metrics

After loading a log, use Parameters to select data for the chart. The Metrics view displays the log metrics table.

Set the start and end date/time to choose the chart and map range. Enable crosshairs to read chart values. Zoom with the mouse wheel and pan by clicking and dragging.

system_params.png channel_params.png input_params.png

log_metrics.png

Map

The map displays recorded GPS coordinates at 1 Hz. Other logged data is recorded at 10 Hz; for each GPS point, the corresponding ten data points appear in the parameter grid.

map.png

I/O Flow

I/O Flow replaces the former I/O Settings editor. It configures input sources, output channels, logic rules and CAN message links as a node graph.

screenshot_2026-11-14_204646.png

Working with the canvas

A digital input, analogue input or ignition source can drive more than one output channel. Each output channel has one incoming control connection. CAN RX signal and system-value nodes are sources for logic-rule operands; use the System CAN Input node for CAN-controlled output channels.

Warning: Connecting a source to an Output Channel stages that channel's enable flag. SAVE CHANGES applies the change to the controller, so verify the output and its connected load are safe before saving.

Node types

Digital Input

Selects one of the PDM's dedicated digital inputs. The electrical mode is fixed as active high; polarity is not configurable. The properties panel shows the live electrical state as High, Low or Unknown.
screenshot_2026-11-14_204801.png

Analogue Input

Selects one of the analogue-capable inputs and edits that input's existing configuration. The node shows live connector voltage and converted value. Any logic rules and output connections follow the node if its source is changed.

Settings depend on the input type:

For an analogue input configured as Digital, a pull-up makes the connector active-low and a pull-down makes it active-high. This is separate from the dedicated digital inputs, which are always active-high.

screenshot_2026-11-14_204906.png

Ignition On

A fixed ignition-input source. It has no editable settings; connect it to output channels that should follow ignition state.

screenshot_2026-11-14_204943.png

System CAN Input

A fixed CAN input source for CAN-controlled outputs. Connect it directly to output-channel nodes that use CAN Digital or CAN PWM behavior. This is distinct from decoded Custom CAN RX signals, which are used as logic-rule inputs.

screenshot_2026-11-14_205224.png

CAN RX Signal

A source node for one enabled, decoded signal on a Custom CAN receive message. Select the signal in Source assignment; its live value is shown on the node. Configure the receive message and signal first in CAN Messages. CAN RX signal nodes connect to logic-rule operands, not directly to output channels.

screenshot_2026-11-14_205109.png

System Value

A source node for one controller value. Select the source in Source assignment; the live value is shown on the node. Available values are:

System Value nodes connect to logic-rule operands.

screenshot_2026-11-14_205310.png

Logic Rule

Combines connected sources and constants. Connect source nodes to the A and, when the selected operation needs it, B input. The properties panel shows live operand values, the rule result and output/rule usage.

Settings:

Rules can use digital inputs, analogue inputs, output channels, other logic rules, CAN RX signal nodes, system values or constants. Logic connections cannot contain cycles.

screenshot_2026-11-14_205429.png

Output Channel

Represents one physical output channel. The properties panel shows live current and active state. Select an available output channel, assign its Category, and set its three-character Channel name. The control source is assigned by wiring into the node.

Available Output behaviour options depend on the connected source:

Other settings are shown as applicable:

screenshot_2026-11-14_205513.png

CAN TX

Transmits a stored Custom CAN TX message when triggered. Select the stored message, enable or disable it, and choose One-shot or Periodic mode. One-shot sends when its trigger turns on; Periodic repeats while the trigger is active.

For Periodic mode, set Period (ms) from 100 to 30,000 ms in 100 ms steps. Connect an Output Channel node to assign the trigger channel. The CAN TX node has no output connector. Configure the frame and signals in CAN Messages.

screenshot_2026-11-14_205625.png

Custom CAN Messages

The CAN Messages tab lets you import signals from a DBC file or define CAN frames and signals manually. CAN RX Signal and CAN TX nodes in I/O Flow use these stored definitions.

screenshot_2026-11-14_205824.png

DBC Import

  1. Select Import DBC File and open the DBC file.
  2. Filter the signal list by signal name if needed.
  3. Review the message, message ID, ID type, signal, start bit, bit length, minimum, maximum and units.
  4. Select the signals to add and choose Import Selected Signals.

The importer skips multiplexed signals because conditional decoding is not supported. It also skips independent signals that are not associated with a CAN message. Cortex reports the number of skipped signals in the import status and system log.

Manual Entry

Define a message (CAN frame), then add its signals. To add a signal to an existing stored frame, select that message; its frame settings are then fixed.

Message settings

Signal settings

Choose Add Signal to Controller to write the signal and, when new, its message. Invalid fields are rejected and shown in the validation summary.

Stored Messages and signals

A CAN TX message must also have a CAN TX node in I/O Flow to be assigned to an output trigger. Changing a message to RX removes its TX node. A CAN RX Signal node is available only for an enabled signal on an RX message.

Connector View

The Connector tab shows the 35-way Ampseal connector diagram, a color legend and a read-only pin summary. Hover over the diagram to identify a pin; use the table to cross-reference the physical role with its configured type, settings, active state, live reading and protection/scaling details.

screenshot_2026-11-14_205912.png

35-way Ampseal pin reference

Pin Physical role Pin Physical role Pin Physical role Pin Physical role
1 Output 3 2 Output 4 3 Output 5 4 Output 6
5 Output 7 6 CAN L 7 CAN H 8 Output 8
9 Output 9 10 Output 10 11 Output 11 12 Output 12
13 Output 2 14 Digital input 1 15 Digital input 2 16 Digital input 3
17 Digital input 4 18 Digital input 5 19 Digital input 6 20 Digital input 7
21 Digital input 8 22 Ignition 23 Output 13 24 Output 1
25 Analogue input 1 26 Analogue input 2 27 Analogue input 3 28 Analogue input 4
29 Analogue input 5 30 Analogue input 6 31 Analogue input 7 32 Analogue input 8
33 5V Reference 34 Ground 35 Output 14

System Settings Tab

screenshot_2026-11-14_205957.png

1. GSM / Data / GPS

2. System

3. CAN

4. Updates

Revert and Save

Once changes have been made, REVERT CHANGES and SAVE CHANGES become available. Revert discards pending controller changes; Save sends them to the controller.

Wait for the save to complete before disconnecting the controller.

Settings Save Status

The main window footer shows Updating PDM while settings are being saved. Afterward, it displays the time settings were last saved to the controller. This is a settings-save timestamp, not a firmware-update or controller-clock timestamp.